Torque Converter and Transmission Assembly Question - Help Needed

Disclaimer: Links on this page pointing to Amazon, eBay and other sites may include affiliate code. If you click them and make a purchase, we may earn a small commission.

Kilian

Full Access Member
Joined
Mar 25, 2018
Posts
214
Reaction score
37
Location
Wisconsin
First Name
K
Truck Year
1983
Truck Model
C2500 on its way to a K2500
Engine Size
350
Hey all, last night I was assembling my rebuilt TH400 with new Torque Converter to the engine and in my first attempt I did not have the torque converter seated completely in the front of the transmission. I didn't realize this until I had attached the transmission bell housing to the back of the engine and couldn't get anything to rotate. Knowing that wasn't correct, I quickly removed the mounting bolts and transmission and discovered that the torque converter could move in just a little further into transmission by turning rear transmission and getting some splines to align.

My question is did I mess anything up by installing things wrong the first time? I know that I had the pump tabs and torque converter slots aligned correctly, and I didn't turn anything in the torque converter/trans because it was too tight for movement, so hopefully what extra pressure was applied didn't mess up torque converter internals. Thanks.
 

Ricko1966

Full Access Member
Joined
Apr 11, 2017
Posts
5,448
Reaction score
8,684
Location
kansas
First Name
Rick
Truck Year
1975
Truck Model
c20
Engine Size
350
Note to self.Read,comprehend,reread then post. Not skim,post, reread understand then delete post. My bad.
 

Vbb199

B-rate Hillbilly Customs
Joined
Jan 12, 2018
Posts
9,040
Reaction score
15,333
Location
Salisbury NC
First Name
Vince
Truck Year
89, 79
Truck Model
89 Suburban R1500, 79 C10
Engine Size
350, 502
As long as you didnt turn it over, which it seems you didnt , i think it'll be ok.

It puts a mess of pressure on the pump gear doing that, but as long as it didnt rotate, it wont hurt the pump
 

Kilian

Full Access Member
Joined
Mar 25, 2018
Posts
214
Reaction score
37
Location
Wisconsin
First Name
K
Truck Year
1983
Truck Model
C2500 on its way to a K2500
Engine Size
350
As long as you didnt turn it over, which it seems you didnt
Correct, didn't rotate anything in engine/transmission because of the tightness.
 

Vbb199

B-rate Hillbilly Customs
Joined
Jan 12, 2018
Posts
9,040
Reaction score
15,333
Location
Salisbury NC
First Name
Vince
Truck Year
89, 79
Truck Model
89 Suburban R1500, 79 C10
Engine Size
350, 502
Correct, didn't rotate anything in engine/transmission because of the tightness.
Its happened to me before haha

Scared me so bad i took the pump apart to inspect it for damage
 

Vbb199

B-rate Hillbilly Customs
Joined
Jan 12, 2018
Posts
9,040
Reaction score
15,333
Location
Salisbury NC
First Name
Vince
Truck Year
89, 79
Truck Model
89 Suburban R1500, 79 C10
Engine Size
350, 502
Same transmission
 

Ricko1966

Full Access Member
Joined
Apr 11, 2017
Posts
5,448
Reaction score
8,684
Location
kansas
First Name
Rick
Truck Year
1975
Truck Model
c20
Engine Size
350
Okay going back to my first post. My first concern was a cracked pump rotor. Then went back and read you had the tabs engaged. Uncertain if once the tabs are engaged you can create enough pressure to damage the pump. My concern is a cracked rotor breaking in use and filling the transmission with shavings. Hopefully @nickstransmissions will chip in here. I did damage a pump once 20+ years ago,and I didn't turn it over,but I did pull thectransmissiin back out and inspect the pump,yes I caused a crack. It was not a turbo 400 it was some fwd Nissan or Mitsubishi minivan at work.
 
Last edited:

Kilian

Full Access Member
Joined
Mar 25, 2018
Posts
214
Reaction score
37
Location
Wisconsin
First Name
K
Truck Year
1983
Truck Model
C2500 on its way to a K2500
Engine Size
350
It seemed like there was a set of splines that hadn't engaged, once I had the engine and transmission separated again, I turned the output shaft of the transmission and then the torque converter slid the last bit into the transmission.
 
Last edited:

NickTransmissions

Supporting Member
Supporting Member
Joined
Aug 3, 2023
Posts
412
Reaction score
851
Location
Las Vegas
First Name
Nick
Truck Year
1987
Truck Model
R10
Engine Size
350
My question is did I mess anything up by installing things wrong the first time?
Not sure where you are with this but if you fill the converter with a quart or two of fluid, install it so it's fully engaged on both sets of splines and the drive gear then start spinning the converter, you will begin to see fluid dribbling out of the supply line fitting on the trans. That tells you the pump is working and everything is mated correctly. Periodically spin it as you move the trans closer to the engine and spin it again once the two have been remarried. If it still feels nice and smooth snd fluid keeps coming from the supply port, you're good.
 

Forum statistics

Threads
44,162
Posts
950,642
Members
36,276
Latest member
2manysquares2care
Top